Jumpers & Indicators
Jumpers
JP9, JP10, JP11


With these jumpers, several settings can be forced
- JP9: Reserved
- JP10: Start with default IP address 172.22.2.100
- JP11: Skip the bootloader
Indicators

The board uses several LEDs indicating activity.
Power

LED1 indicates that the external power is connected, this means that 24V and 5V are available.

PWR This LED indicates that the power for the processor is available (3.3V).
Network

Yellow = Network activity (ACT) Green = Network connection (LNK)
Status

Indicator | Color | Meaning |
LED6 | Red | SYSREADY indicates when CNC system is ready for operation. Can be used in cooperation with safety relay. |
LED5 | Red | WATCHDOG charge pump, indicates operation of the watchdog circuitry |
LED4 | Green | Controller ‘heartbeat’ indicating the board is active |
LED3 | Green | Indicates ‘Machine On’ |
LED2 | Green | Flashing when application is starting up. After startup, will be switch ON if E-STOP occurred. |
Please note, when in bootloader mode LED2 and LED3 will toggle to indicate this.