`M1` All heating and Fans off

`M100 P...` Change A axis resolution during execution by a factor (factor 1 is standard, 1.01 is 1% more, 0.99 is 1% less.

`M104 S...` Set extruder temperature, (`M104 S50` sets the temperature to 50 degrees *Celsius*).

`M106 S...` Workpiece cooling fan on optionally with S=0-100, for 0-100% *PWM*

`M107` Work piece fan off

`M109 S...` Set the extruder temperature and wait until it is reached.

`M140 S...` Set bed temperature.

`M143 S...` Set maximum hot-end temperature to prevent overheating.

`M190 S...` Set the bed temperature and wait until reached.