S1000 - S1099
we are working hard to document every message and error if any message is not described or the description is incomplete, contact us for more detailed information s1000 machine service time interval expired the time interval as set up in the service tab has expired the machine should be serviced as specified by the machine's manufacturer s1001 machine service traveling distance interval expired the distance interval as set up in the service tab has been exceeded the machine should be serviced as specified by the machine's manufacturer s1002 motion state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1003 motion state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1004 motion state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1005 motion state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1006 trivial kinematics expected for c to b mapping the use of this function requires the machine to use trivial kinematics this error is caused when using the tanknife command in combination with non trivial kinematics s1007 motion state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1008 trivial kinematics expected for 45 degree bent tan knife the use of this function requires the machine to use trivial kinematics this error is caused when using the tanknife command in combination with non trivial kinematics s1009 cannot switch simulation mode in state = \<state name> if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1010 change motion state to idle failed the motion controller state could not be set to idle if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1011 switch to real mode failed the system could not be set to real mode from simulation mode if this error occurs when using our software directly, please contact us with a detailed description and a support archive s1012 safety feed, please home the machine! the machine travels at safety feed because not all axes were homed home all axes of the machine to activate the full speed s1013 safety feed, master/slave not equal, hometandem first! the machine travels at safety feed because the master and slave axis are not equal this occurs when not using gantry squaring/tandem homing correctly the macro for the slave axis should never contain a home \<slave axis letter> command only a tandemhome \<axis letter> s1016 reset cpu failed the controller could not be reset because the communication was lost check that the usb or ethernet cable is firmly inserted on both sides check the indicators on the controller to see if the controller is still powered and active when using usb, be mindful that certain devices (vfds, motor drivers) emit large amounts of emi and can interfere with the signal always route the cable as far away from these devices as possible s1019 controller state = simulation a connection could not be established to the machine, the software started in a simulation mode this mode will not reattempt the connection and therefore no actions will result in movements on the machine if a connection to the machine is desired and the machine was powered and connected, check https //docs edingcnc com/network setup for details on how to set up windows for a controller with ethernet s1020 new configuration file created no configuration file was found so a new one was created if the machine was previously set up and that configuration is supposed to be used, locate the file and ensure that the location matches the location specified in the docid 5rst332xvtocvh6vvzcxm setting with the software closed, place the file in the appropriate location and start the software again s1021 welcome, you can move the axes by arrow keys this message shows when the software was started in simulation mode the simulated machine can be moved in x/y using the arrow keys, and in z using the page up/page down keys s1022 configuration file restored, check tool and offsets the configuration file was restored from a backup because the original file could not be read check that the backup matches the settings and variables s1023 kinematics is not enabled, please contact supplier the selected kinematics are not enabled for this machine, contact the manufacturer of your machine or the developer of the kinematics to resolve this error s1024 controller state = operational usb a usb based controller was detected and connected s1025 welcome, press reset (f1) to enable drives the message shows when the software is started with a controller attached to start the machine, press the reset button s1026 controller state = operational eth an ethernet based controller was detected and connected s1027 welcome, press machon to switch machine on this message shows when the machine uses a safety relay, and it is not switched on yet press the traffic light button to turn the safety relay on s1028 cpu is not enabled for \<language>, please contact supplier the controller is activated to only be used with a certain os language contact the seller of the controller or machine s1029 cpu is not enabled, please contact supplier the controller is not enabled, most likely, the license had a time limit that has expired in the past contact your machine's manufacturer for an updated license code s1030 cpu is not enabled for this sw version, please contact supplier the controller license is only valid up to a certain version before this version contact the supplier of the controller or machine for a resolution s1031 cpu is not enabled for avx board, please contact supplier the controller license does not permit the use of an avx board, contact the supplier of the controller or machine s1032 cpu activation date expired, please contact supplier the controller has a license that is locked to a date, this date has passed and the controller is now locked contact the manufacturer of your machine to get a new license code s1033 \<current version> wrong firmware, download \<correct version> the firmware of the controller is not supported by this software version download the correct version by following the steps outlined in docid\ pz3xehfi limmffti kyb these steps may differ based on the hardware s1034 a cpu connection error occurred, please contact supplier for ethernet controllers either the ip address may be invalid, or the pc is unable to detect controllers on this ip address for usb controllers the com port may be wrong if this error occurs while the ip address is correct, contact the edingcnc team and include as much information as possible on how this occurred s1035 sync update failed, please contact eding cnc the sync update failed; this means that the motion controller task is stuck if this error occurs, contact the edingcnc team and include as much information as possible on how this occurred s1039 reset cpu failed the controller could not be reset because the communication was lost check that the usb or ethernet cable is firmly inserted on both sides check the indicators on the controller to see if the controller is still powered and active when using usb, be mindful that certain devices (vfds, motor drivers) emit large amounts of emi and can interfere with the signal always route the cable as far away from these devices as possible s1041 reset cpu failed the controller could not be reset because the communication was lost check that the usb or ethernet cable is firmly inserted on both sides check the indicators on the controller to see if the controller is still powered and active when using usb, be mindful that certain devices (vfds, motor drivers) emit large amounts of emi and can interfere with the signal always route the cable as far away from these devices as possible s1042 reset cpu failed the controller could not be reset because the communication was lost check that the usb or ethernet cable is firmly inserted on both sides check the indicators on the controller to see if the controller is still powered and active when using usb, be mindful that certain devices (vfds, motor drivers) emit large amounts of emi and can interfere with the signal always route the cable as far away from these devices as possible s1043 please switch machine on the machine has a safety relay, which is not switched on press the traffic light button in the left menu on the operate tab to enable the safety relay s1044 drivers switched on the motor drivers are enabled after the safety relay was switched on s1045 estop2 active, please reset the e stop2 is active; resolve the error and press reset s1046 estop active, please reset the e stop is active; resolve the error and press reset s1047 external error active, please reset the external error is active; resolve the error and press reset s1048 drive alarm active, resolve and press reset the drive alarm is active; resolve the error and press reset s1049 feed hold is active the feed override value could not be updated because the feed hold is active s1050 feed override is disabled the feed override value could not be updated because the feed override is disabled s1051 not initialized the home or probe movement could not be completed because the system is not initialized if this error occurs, contact the edingcnc team and include as much information as possible on how this occurred s1052 forward kinematic failure the home or probe movement could not be completed because the kinematics could not resolve a cartesian position for this point s1070 zhc is already on z height compensation was already on when trying to switch it on s1074 zhc is switched on z height compensation was turned on s1075 zhc is already off z height compensation was already off when trying to switch it off s1077 zhc is switched off z height compensation was turned off s1078 pitch comp is already off pitch compensation was already off when trying to switch it off s1080 pitch comp is switched off pitch compensation was turned off s1081 cross comp is already on cross compensation was already on when trying to switch it on s1083 cross comp is switched on cross compensation was turned on s1084 cross comp is already off cross compensation was already off when trying to switch it off s1087 cross comp is switched off cross compensation was turned off